HKV6

Maximum 100mΩ at initial value. 
Test Current: 1A, Open Circuit Test Voltage: 6VDC.

By using Voltage Drop Method

 

 

Safety Standard :  C-UL

 

 

Contact Gap 0.25 mm Minimum
Contact Resistance

Maximum 100mΩ at initial value.
Test Current: 1A, Open Circuit Test Voltage: 6VDC.

By using Voltage Drop Method
Contact Capacity

5 Amps at 250VAC Cosφ=1.

20 Amps at 14VDC

 

 

Rated Voltage 3VDC 5VDC 6VDC 9VDC 12VDC 24VDC
Nominal Current( mA± 10%) 200/268 119-156 100/130 67/89 50/67 25/33
Rated Power Consumption (± 10%) 0.6W/0.8W
Coil Resistance 15/11.2 42/31.3 60/45 135/101 240/180 960/720
Pull In Voltage

≦  (Contact operating voltage when voltage is gradually applied.  It is 75% of the Rated Voltage) V DC

Drop Out Voltage

≧ (Contact breaking voltage when rated voltage is gradually reduced.  It is 10% of the Rated Voltage) VDC

Max. Allowable Voltage

(130% of the Rated Voltage) V DC

Operate Time 10 milliseconds Maximum when rated Voltage is applied
Release Time 10 milliseconds Maximum when rated Voltage is suddenly cut off.
Coil Temperature Rise

40℃ Maximum.Maximum Allowable Voltage is applied to Coil while no load should be applied to Contacts, then the temperature should be measured when the value is stabilized.  Environment temperature should not be included in.

 

 

Life Expectancy

Electrical Life:100,000 operations Minimum at 5A/250VAC Cosφ=1. 100,000 operations Minimum at20A/14VDC  Rated Voltage is applied

10,000,000 operations Minimum at No Load condition.
Maximum Operating Frequency :Electrical: 30 operations/minute Mechanical: 300 operations/minute.
Dielectric Strength Between Contacts:500VAC at Test Frequency 50/60 Hz, Leakage Current: 1mA for 1 minute
Between Coil & Contact: 500VAC at Test Frequency 50/60 Hz, Leakage Current: 1mA for 1 minute.
Insulation Resistance

≧1000 MΩ Minimum.A Voltage of 500VDC should be applied after which measurement shall be made.

Vibration Endurance I: The Coil shall be maintained under not energized condition, double amplitude 1.5 mm, the entire frequency range changes from 10 to 55 Hz then returns to 10 Hz shall be made in 1 minute.  This motion shall be applied for a period of 2 hours in each of 3 mutually perpendicular axis (a total of 6 hours) There should not be any deformations in construction and in appearance, while the Electrical Specifications should be fulfilled after the test.
Endurance II (Error Operation):The Coil shall be maintained under energized condition, double amplitude 1.5 mm, the entire frequency range changes from 10 to 55 Hz then returns to 10 Hz shall be made in 1 minute.  This motion shall be applied for a period of 5 minutes in 3 mutually perpendicular axis.  Malfunction is not allowed during the test (contact breaking time should be less than 1 millisecond) In addition, there should not be any deformations in construction and in appearance while the Electrical Specifications should be fulfilled after the test.。
Shock Endurance I:Peak Acceleration: 1000m/s2 The Coil shall be maintained under not energized condition, 5 successive shocks shall be applied in 3 mutually perpendicular axis.  There should not be any deformations in construction and in appearance while the Electrical Specifications should be fulfilled after the test.
Endurance II (Error Operation):Peak Acceleration: 100m/s2 The Coil should be maintained under energized condition, 2 successive shocks shall be applied in 3 mutually perpendicular axis.  Malfunction is not allowed during the test (contact breaking time should be less than 1 millisecond) In addition, there should not be any deformations in construction and in appearance while the Electrical Specifications should be fulfilled after the test.

 

 

Temperature Range Operating Temperature Range:-30 to + 85°C。
Operating temperature range is the range of ambient temperature of which the Relay can be operated continuously within operative voltage range of coil (no condensation of water drops under low temperature condition)
Storage Temperature Range:-30 to + 85°C.
Storage temperature range is the range of ambient temperature of which the Relay can be stored without damages (no condensation of water drops under low temperature condition).  Conditions are as specified elsewhere in these specifications.
Humidity Range 35~85% RH
Cold Resistance Cold Resistance in Use:Relay should be kept in temperature chamber at -30 ± 2°C for two hours that no current or voltage shall be supplied to Relay.  Such condition shall be maintained while the rated voltage is supplied to Relay, then the Relay shall operate normally. (No condensation of water drops under low temperature condition)
Storage Cold Resistance:Relay should be kept in temperature chamber at -40 ± 2°C for 72 hours.  Then the Relays shall be maintained at standard atmospheric condition for 1 to 2 hours after which measurement shall be made.  Construction, Relay operation, Insulation Resistance and Dielectric Strength shall satisfy the specification requirements.  (No condensation of water drops under low temperature condition)
Heat Resistance Heat Resistance in Use::Relay should be kept in temperature chamber at 70 ± 2°C for two hours that rated Voltage should be supplied to Coil while rated Current should be supplied to Contacts.  Such condition shall be maintained while the rated voltage is supplied to Relay, then Relay shall operate normally
Storage Heat Resistance:Relay should be kept in temperature chamber at 70 ± 2°C for 16 hours.  Then the Relays shall be maintained at standard atmospheric condition for 1 to 2 hours after which measurement shall be made.  Construction, Relay operation, Insulation Resistance and Dielectric Strength shall satisfy the specification requirements
Moisture Resistance

Relay should be kept in temperature chamber at 40 ± 2°C (90~95% RH) for 48 hours.  Then the Relays shall be maintained at standard atmospheric condition for 1 to 2 hours after which measurement shall be made.  Construction, Relay operation, Insulation Resistance, Dielectric Strength shall satisfy the specification requirements

 

 

Terminal Strength

A load of 300g should be applied to the Terminal for one minute in horizontal direction.  There should not be any looseness or bending of Terminals

Soldering Dip Test

The front 3 mm of Terminal should be immersed for 3 ± 0.5 seconds at 230 ± 5°C.  Soldered area must be minimum 90% of the soldering surface

Soldering Heat Resistance

When the Terminal are immersed into soldering bath at 350 °C for 3 seconds, the Relay shall satisfy all electrical and mechanical specifications and must not have excessive change in outside appearance.

 

 

Weight:Approx.6g

 

 

Sample Test Method:GB2828-2000 Level – General II, AQL 0.4.

 

 

HKV6 -DC 12V -S H A G
Special Request Code   G:RoHS
Mounting Termination NIL:PCB
Contact Form NIL:1FormC  A:1FormA  B:1FormB
Coil Power NIL:0.6W    H:0.8W
Type  Of  Sealing  NIL:Flow Solder Type S:Plastic Sealed Type
Coil Voltag  3V、5V、 6V、9V、12V、24V
CoilType DC:DC
Type HKV6

 

 

 

 

 

 

 
Type Inner packaging method Carton Size The total amount Net weight (Kg) Gross weight (Kg)
L * W * H
HKV6 200 / tube (5 tubes per box, a total of 2 boxes) 41*30*16 2000/box 10.6 12.5